Non-Wetted Electrode Electromagnetic Flow Sensors
FD-M series
Amplifier Unit, DIN Rail Mount Type, Main Unit, PNP FD-MA1AP
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | FD-MA1AP*1 | |||
Type | DIN mounted*2 (Main unit) | |||
Rated flow range | FD-MH10A : 0.5 to 10L/min, FD-MH50A : 2.5 to 50L/min, FD-MH100A : 5 to 100L/min, FD-MH500A : 25 to 500L/minThe rated flow range indicates the range that is supposed to be used in general.*3 | |||
Possible display range | FD-MH10A : 0.5 to 20L/min, FD-MH50A : 2.5 to 100L/min, FD-MH100A : 5 to 200L/min, FD-MH500A : 25 to 1000L/min*4 | |||
Possible ranges to set | FD-MH10A : 0 to 20 L/min,FD-MH50A : 0 to 100 L/min,FD-MH100A : 0 to 200 L/min,FD-MH500A : 0-999.9 L/min | |||
Zero-cut flow rate | FD-MH10A : 0.5L/min, FD-MH50A : 2.5L/min, FD-MH100A : 5L/min, FD-MH500A : 25L/min*4 | |||
Display power | Dual row display with 4-digit, 7 segment LED, other indicators | |||
Display resolution | FD-MH10A: 0.01/0.1 (L/min) selectable, FD-MH50A: 0.1/1 (L/min) selectable, FD-MH100A: 0.1/1 (L/min) selectable, FD-MH500A: 0.1/1 (L/min) selectable | |||
Repeatability | 0.5 s : ±5% of F.S.,1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*5 | |||
Hysteresis | Variable | |||
Response time (chatter prevention feature) | 500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s variable | |||
Accumulated flow unit | FD-MH10A : 0.01/0.1/1/10/100 (ℓ) selectable,FD-MH50A : 0.1/1/10/100/1000 (ℓ) selectable,FD-MH100A : 0.1/1/10/100/1000 (ℓ) selectable,FD-MH500A : 1/10/100/1000/10000 (ℓ) selectable | |||
Accumulation data storage cycle | Save to memory every 10 seconds | |||
Memory backup | EEPROM (Data storage length : min. 10 years, Data read/write frequency : min. 1 million times) | |||
Control output | Maximum PNP open-collector output : 100 mA/ch*6 (30 V or less) | |||
Analogue output | 4-20 mA, max. load resistance 260Ω, Analogue output range can be set to any value | |||
Integration reset/bank switch input/flow zero function input | |input time : 20 ms or greater, Either accumulation reset or bank switching mode can be selected | |||
Power/current consumption | Normal : 1700 mW (70 mA), Power save : 1440 mW (60 mA) | |||
Rating | Power voltage | 24 VDC, Ripple (P-P) 10 % or less | ||
Environmental resistance | Ambient temperature | 0 to +50 °C (No freezing) | ||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |||
Material | Main case : polycarbonate, Key tops : polyacetal, Front sheet : polycarbonate, Cable : PVC | |||
Accessories | instruction manual | |||
Weight | Approx. 115 g | |||
*1 The models with “A” at the end of the name have additional functions such as display averaging. Use the head with “A” at the end of the name. When connecting conventional heads without “A” at the end, the FD-MH operates in the same way |