Profile Controller LJ-X8000A

LJ-X8000A - Profile Controller

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

LJ-X8000A

Head input

1 unit, compatible with LJ-X8000 Series heads and LJ-V7000 Series heads

Sampling cycle (trigger interval)

When connecting the LJ-X8000 Series: maximum speed of 16 kHz (63 μs) *1
When connecting the LJ-V7000 Series: maximum speed of 64 kHz (16 μs) *2
(Luminance output types for model designations ending with B have a maximum speed of 8 kHz (125 μs)) *3

Interface

Control input

Compatible with batch measurement start (MEASURE_START) and batch measurement stop (MEASURE_STOP)

Control output

Compatible with trigger ready (READY) and system error (ERROR), Photo MOSFET *4

Synchronised I/O

For multiple controller trigger synchronisation *5

Ethernet

Profile output, settings, control, 1000BASE-T/100BASE-TX*6

Encoder input

1 port: combination RS-422 line-driver output (with 5 V output: maximum 150 mA) open collector output (compatible with 5 V, 24 V)

Response frequency

RS-422

Single phase / Z phase: 1.6 MHz, 2 phase / 1x: 1.6 MHz, 2 phase / 2x: 3.2 MHz, 2 phase / 4x: 6.4 MHz

Open collector (OC)

Single phase / Z phase: 100 kHz, 2 phase / 1x: 100 kHz, 2 phase / 2x: 200 kHz, 2 phase / 4x: 400 kHz

Laser ON input

Non-voltage input (Shorted with short pin when shipped from factory)

Ratings

Power voltage

24 V DC ±10%

Maximum current consumption

1.3 A

Environmental resistance

Ambient temperature

0 to 45°C (DIN rail mounting) / 0 to 40°C (Horizontal)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 700 g

*1 When the measurement range is narrowed in accordance with the binning settings.
*2 When the measurement range is set to minimum, binning is ON, and parallel imaging is ON. All other settings are default values.
*3 When binning and parallel imaging are both ON. All other settings are default values.
*4 Positive common connection is supported for NPN input devices, and negative common connection for PNP input devices.
*5 Exclusively for synchronised I/O between controllers (LJ-X8000A).
*6 The PC application (LJ-H2X) includes communication libraries (DLL) and a sample programme. Types of communication libraries (DLL): Profile output, changing various settings, laser ON/OFF control, trigger input, etc.

Data Sheet (PDF) Other Models