High-speed, High-accuracy Digital Micrometer
LS-7000 series
Specs High-speed, High-accuracy Digital Micrometer LS-7000 series
Measuring head: Large-diameter type/Standard type
Model |
LS-7070M |
LS-7070 |
LS-7030M |
LS-7030 |
|||
Image |
|
|
|
|
|||
Type |
Large-diameter |
Standard |
|||||
Classification |
with monitor camera |
without monitor camera |
with monitor camera |
without monitor camera |
|||
Measurement range |
0.5 to 65 mm |
0.3 to 30 mm |
|||||
Smallest detectable object |
0.5 mm |
0.3 mm |
|||||
Transmitter/receiver distance |
250 ±50 mm |
160 ±40 mm |
|||||
Repeatability |
±0.2 µm*1 |
±0.15 µm*5 |
|||||
Measurement accuracy |
±3 µm*2 |
±2 µm*6 |
|||||
Sampling cycle |
2,400 samples/sec.*3 |
||||||
CCD scanning range |
Approx. 69 mm |
Approx. 33 mm |
|||||
Light source |
GaN green LED |
||||||
Monitor camera |
Provided |
Not provided |
Provided |
Not provided |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
|||||
Ambient temperature |
0 to +50 °C |
||||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Weight |
Transmitter: Approx. 540 g |
Transmitter: Approx. 540 g |
Transmitter: Approx. 420 g |
Transmitter: Approx. 420 g |
|||
*1 The value of ±2σ when the outer diameter of a rod 20 mm in diameter is measured at the centre of the measuring area while the number of averaging measurements is set to 512. |
Measuring head: Small-diameter type
Model |
LS-7010M |
LS-7010 |
|||
Image |
|
|
|||
Type |
Small-diameter |
||||
Classification |
with monitor camera |
without monitor camera |
|||
Measurement range |
0.04 to 6 mm |
||||
Smallest detectable object |
0.04 mm |
||||
Transmitter/receiver distance |
60 ±5 mm |
||||
Repeatability |
±0.06 µm*1 |
||||
Measurement accuracy |
±0.5 µm*2 |
||||
Sampling cycle |
2,400 samples/sec.*3 |
||||
CCD scanning range |
Approx. 7 mm |
||||
Light source |
GaN green LED |
||||
Monitor camera |
Provided |
Not provided |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
|||
Ambient temperature |
0 to +50 °C |
||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||
Weight |
Transmitter: Approx. 140 g |
Transmitter: Approx. 140 g |
|||
*1 The value of ±2σ when the outer diameter of a rod 1 mm in diameter is measured at the centre of the measuring area while the number of averaging measurements is set to 512. |
Controller
Model |
LS-7601*1 |
LS-7001*1 |
|||
Image |
|
|
|||
Type |
High-performance |
Standard |
|||
No. of connectable sensor heads |
2 (fully compatible for all head types) |
2 (fully compatible for all head types except monitor (M) models) |
|||
Display |
Measurement display |
TFT 5.5-inch LCD display |
Main display: 7-segment red LED (Character height: 20.3 mm) |
||
Minimum display unit |
0.01 to 100 µm (7-level selectable) |
||||
Display range |
±99.99999 to 9,999.9 mm (Linked to minimum display unit setting, mm/µm selectable) |
||||
Measurement position monitor |
Monitor image (When the measuring head with the monitor function is connected.) |
7-level display with a red LED |
|||
Tolerance check output display |
5-level LCD indicator |
Green LED (GO), Red LED x 2 (HI, LO) |
|||
Input terminal block |
Synchronous 1, 2 input |
Non-voltage input for OUT1 |
|||
Auto-zero 1, 2 input |
|||||
Reset 1, 2 input |
|||||
Statistics 1, 2 input |
Non-voltage input for OUT1 |
- |
|||
Program selection input |
Non-voltage input x 4 inputs |
||||
Output terminal |
Analogue voltage output |
±10 V x 2 outputs |
|||
Alarm output |
NPN open-collector output (N.C.) |
||||
Total judgment output |
NPN open-collector output for OUT1 |
||||
Comparator ready output |
|||||
Strobe 1, 2 output |
|||||
Connector I/O |
SUB mode |
Statistical processing output |
NPN open-collector output x 2 outputs*2 |
- |
|
Function output |
Selectable from focus, area check, and differential, NPN open-collector output x 2 outputs*2 |
||||
5-level comparator output |
NPN open-collector output for OUT2*2 |
||||
Comparator ready output |
|||||
Strobe output |
|||||
BCD mode |
BCD output |
Measurement data output (Sign + 7 digits), OUT1/OUT2 selectable, NPN open-collector output*2 |
|||
BCD selection output |
NPN open-collector output*2 |
||||
BCD selection input |
Non-voltage input*2 |
||||
Statistical processing input |
Non-voltage input for OUT2 |
- |
|||
Synchronous input |
Non-voltage input for OUT2 |
||||
Reset input |
|||||
Auto-zero input |
|||||
Interface |
RS-232C |
Measurement data output and control I/O, printer (Baud rate can be selected up to 115,200 bps.) |
|||
Video output |
Conforming to the NTSC system (PIN connector) |
- |
|||
Major functions |
Simultaneous measurement, Area designation, Calculation, Averaging, Calibration, 16-program memory, |
Simultaneous measurement, Area designation, Calculation, Averaging, Calibration, 16-program memory, |
|||
Rating |
Power voltage |
24 VDC ±10 %*3 |
|||
Power consumption |
1.2 A max.*3 |
0.7 A max.*3 |
|||
Environmental resistance |
Enclosure rating |
IP64 (Panel surface only) |
|||
Ambient temperature |
0 to +40 °C |
||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||
Weight |
Approx. 1,010 g |
Approx. 820 g |
|||
*1 The rating of the NPN open-collector inside the terminal block is: 100 mA max. (40 V max.), residual voltage of 0.5 V max. |
Setting support software
Model |
LS-H1W |
|||
Image |
|
|||
Type |
Setting support software |
|||
Operating System |
Windows 11 Pro |
|||
CPU |
Pentium III 400 MHz or higher |
|||
Memory capacity |
64 MB or more |
|||
Available hard disk space |
10 MB or more |
|||
Display |
VGA (800 x 600 pixels) or more, 256 colours or more |
|||
PC interface |
RS-232C (serial port) interface required |
|||
Note |
Excel: Excel 2010/2007/2003/2002/2000 |
|||
*1 Home, Pro, and Enterprise editions are supported. |