Short range amplifier unit with separate display M8 Connector Type Main Unit FR-SA1C

FR-SA1C - Short range amplifier unit with separate display M8 Connector Type Main Unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

FR-SA1C

Type

Short Separated Amplifier Unit M8 connector Main Unit

Response time

0.4 s, 1.5 s, 4 s (default value), 10 s

Output

No. of control outputs

Maximum 2

Control output/auxiliary output

NPN/PNP open collector (switchable)
Up to 30 VDC or less, max 50 mA for each
Residual voltage of 1.4 V or less (50 mA or less)
N.O./N.C. Switching type
IO1 used in combination with IO-Link
IO2 is used in conjunction with analogue output/external input

Analogue output

0–20 mA/4–20 mA
Maximum load resistance 260 Ω
(Response time: 0.2 s (90% response) after control output is confirmed)

External input

Short circuit current: 1.5 mA or less Input time: 500 ms or more

External communication

IO-Link v1.1/COM2

Analogue output Precision

Resolution

1 mm *1

Zero accuracy

±0.1 mA (zero point = 4 mA) *1

Full-scale accuracy

±0.2 mA (full-scale = 20 mA) *1

Expansion

Power supply

Power voltage

24 VDC +25%/−20%*2*3 including ripple, Class2 or LPS

Power consumption

1880 mW or less (63 mA or less at 24 V) (Excluding Load Current)

Environmental resistance

Ambient temperature

–20°C to +55°C (no freezing) *4

Relative humidity

Up to 85% RH (no condensation)

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges

Material

PC

Weight

Approx. 20 g

*1 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment.
*2 When expanding the FR-SA2 with the number of units indicated on the right or more, use a power voltage of 21.6 V or higher. When FR-S01 is connected: 1 unit; when FR-SH01 is connected: 8 units.
*3 When expanding the system by four or more FR-SA0 units with the FR-S01 connected or by ten or more FR-SA0 units with the FR-SH01 connected, use a power voltage of 21.6 V or higher.
*4 If the number of expansion units is one, the ambient temperature must be 50°C or less, and if the number of expansion units is two or more, the ambient temperature must be 45°C or less.

Data Sheet (PDF) Other Models