Short range sensor head with separate display Compact liquid chemical model FR-SH01

FR-SH01 - Short range sensor head with separate display Compact liquid chemical model

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

FR-SH01

Type

Short range Compact liquid chemical model

Measuring range

Up to 1.5 m *1

Display range

Up to 2 m *1

Measurable dielectric constant of medium

2 or higher *2

Resolution

1 mm

Precision

Up to 0.1 m: ±20 mm;
0.1 to 0.3 m: ±5 mm;
0.3 to 1.5 m: ±1 mm
*3

Response time

0.4 s, 1.5 s, 4 s (default value), 10 s

Tank pressure

-0.1 to +0.1 MPa

Material

Tank interior

Lens: PTFE
Internal packing: FKM
Joint: PPS

Housing

PPS PPSU

Connection diameter

G3/4 (20 A)

Output

No. of control outputs

Control output/auxiliary output

Analogue output

External input

Network compatibility

Analogue output Precision

Resolution

Zero accuracy

Analogue output accuracy

F.S. accuracy

Power supply

Power voltage

Current consumption

Environmental resistance

Ambient temperature

–10 to +70°C *4 *5
(No freezing)

Relative humidity

Up to 85% RH (no condensation)

Temperature of coupling used

–10 to +85°C (no freezing) *4 *5

Vibration resistance

10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions

Shock resistance

100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Enclosure rating

IP67 (IEC60529)

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges

Weight

Approx. 140 g

*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created owing to the environment and measurement medium. The maximum measuring distance is also shortened.
*2 Measurement may not be possible depending on the shape and environment of the target.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement errors may occur depending on the customer’s environment.
*4 Details of the operating temperature range of each model are shown below. The FR-S01 and FR-LM20/LP20 can be used up to an ambient temperature setpoint of 10°C by selecting “Off when not in Operation” under “Screen Brightness.”
*5 When performing SIP with FR-S01/FR-LM20/LP20/LS20, be sure to turn off the power and perform at an ambient temperature of 40°C or less and an internal temperature of 130°C or less for up to one hour. In addition, always install the KEYENCE optional ferrule mounting bracket and internal gasket.