Two-colour Digital Display Pressure Sensor
AP-30 series
Specs Two-colour Digital Display Pressure Sensor AP-30 series
Main unit: PNP
Model |
AP-31P |
|||
Image |
|
|||
Type |
Negative pressure, PNP |
|||
Rated pressure |
0 to -1.013 bar (0 to -101.3 kPa) |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-colour, 7-segment LED (Character height: 11 mm) |
|||
Display resolution |
0.001 bar, 0.1 inchHg, 0.1 kPa, 1 mmHg |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Display temperature characteristic |
±1 % max. (of F.S.) of detecting pressure at 25 °C (0 to 50 °C) |
|||
Temperature fluctuation for analogue output |
±2 % max. (of F.S.) of detecting pressure at 25 °C (0 to 50 °C) |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analogue output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
2 PNP open-collector: 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
5.0 bar (500 kPa) |
||
Ambient temperature |
0 to +50 °C (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, |
|||
Weight |
Approx. 120 g (including 2 m cable) |