CIP Safety™ Type (with camera) SZ-V32NCX

SZ-V32NCX - CIP Safety™ Type (with camera)

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

SZ-V32NCX*1

Type

CIP Safety™ Type

Detection
capability

Minimum detectable object size

Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting);
Reflectance: 1.8% min.; Speed: 1.6 m/s max.*2

Detectable angle

190° (-5° to 185°)

Response time
(ON to OFF)

Standard Mode

Scan Cycle A

160 ms (2 scans) to 1280 ms (16 scans)*3*4

Scan Cycle B

168 ms (2 scans) to 1344 ms (16 scans)*3*4

Scan Cycle C

176 ms (2 scans) to 1408 ms (16 scans)*3*4

High Speed Mode

Scan Cycle A

80 ms (2 scans) to 640 ms (16 scans)*3*4

Scan Cycle B

84 ms (2 scans) to 672 ms (16 scans)*3*4

Scan Cycle C

88 ms (2 scans) to 704 ms (16 scans)*3*4

Response time (OFF to ON)

Response time of ON to OFF + 150 ms

Protection
zone

Minimum detectable object size: 70 / 150 mm

Standard Mode: 8.4 m / High Speed Mode: 5.7 m

Minimum detectable object size: 50 mm

Standard Mode: 5.6 m / High Speed Mode: 3.8 m

Minimum detectable object size: 40 mm

Standard Mode: 4.3 m / High Speed Mode: 2.9 m

Minimum detectable object size: 30 mm

Standard Mode: 2.9 m / High Speed Mode: 2.0 m

Minimum detectable object size: 20 mm

Standard Mode: 1.6 m / High Speed Mode: 1.1 m

Warning
zone

Minimum detectable object size: 70 / 150 mm

Standard Mode: 26 m / High Speed Mode: 23 m*5

Minimum detectable object size: 50 mm

Standard Mode: 25 m / High Speed Mode: 21 m*5

Minimum detectable object size: 40 mm

Standard Mode: 24 m / High Speed Mode: 20 m*5

Minimum detectable object size: 30 mm

Standard Mode: 23 m / High Speed Mode: 18 m*5

Minimum detectable object size: 20 mm

Standard Mode: 21 m / High Speed Mode: 15 m*5

Additional safety distance

100 mm*6

Maximum measurement distance

60 m*7

Maximum number of banks

Max. 16 banks

Multiple scanner heads

Max. 3

Camera

Monitor area: over 190° (-5° to 185°)*8

Display

QVGA 2.2 inch colour LCD

Light source

Type, wavelength

Infrared laser diode, 905 nm

Laser class

IEC

Class 1 IEC / EN 60825-1

FDA

Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice)*9

JIS

Class 1 JIS C6802

Control output
(OSSD output)

Output type

-

Number of outputs

Max. load current

Residual voltage

OFF-state voltage

Leakage current

Max. capacitive load

Load wiring resistance

Input
(safety-related)

PNP

NPN

Non
safety-related
output
(AUX output)

Output type

Number of outputs

Max. load current

Residual voltage (during ON)

Muting lamp

Interface

USB

USB 2.0

Ethernet

Standard

IEEE802.3u (100BASE-TX)

Transmission rate

100 Mbps

Cable

Category5 or higher STP (Shielded Twisted Pair)
or UTP (Unshielded Twisted Pair) cable

Connector

RJ45 (IP65 connector) 2 ports

Networking/data output

CIP Safety™, EtherNet/IP™, UDP

Cable length

Power cable

30 m or less*10

Connection cable

20 m or less each*11

Ethernet cable

100 m or less*12

Approved
standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE)

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE),
IEC61496-3, EN61496-3 (Type3 AOPDDR),
IEC61508, EN61508,
EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3,
UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8

Rating

Power consumption

13.4W*13

Power voltage

When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less
When using a battery: 24 VDC +20 % /-30 %

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient light

Incandescent lamp: 1,500 lux or less*14

Operating ambient temperature

-10 to +50 °C (No freezing)

Storage temperature

-25 to +60 °C (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage relative humidity

35 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Scanner head

Main unit case

Magnesium

Window

Polycarbonate, PEI

Indicator part

Aluminum, PES*8

Display unit

case

Magnesium, PPS, Polycarbonate

System memory

Aluminum, PPE

Weight

Approx. 2,300 g

*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005).
*2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting.
*3 The response time, protection zone, and warning zone are affected by the operation mode.
*4 When PROFIsafe is used with the SZ-V32N, 6 ms is added to the response time.
*5 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*6 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance.
*7 Even when using the network data output, the maximum measured output distance is 60 m.
*8 Only applicable for the type with a camera.
*9 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*10 10 m or less when supplying power from a battery.
*11 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads.
*12 Distance between SZ-V and Ethernet switch
*13 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation.
*14 An ambient light source should not be located within ±5° of the detection plane.

Data Sheet (PDF) Other Models