Holding force 900N M12 Connector type Advanced function type PNP GS-M93P

GS-M93P - Holding force 900N M12 Connector type Advanced function type PNP

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

GS-M93P

Type

For hinged door High-holding force M12 Connector Advanced function

Holding force when locked

900N

Holding force when unlocked

Approx. 50N *1

Cascading

Max. 16 units

Operating distance

Sao(OFF→ON)

0.1 mm *2

Sar(ON → OFF)

15 mm *2

Response time (ms)

Lock→Unlock

250 ms *3

Unlock→Lock

Detect→ Not detect

20 ms + 2 ms × (number of cascaded unit -1) *3

Not detect→ Detect

300 ms + 25 ms × (number of cascaded unit -1) *3

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

150 mA

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m)
Max. 3.5 V (with a cable length of 31 m)

OFF state voltage

Max. 2.0 V (with a cable length of 5 m)
Max. 3.0 V (with a cable length of 31 m)

Leakage current

Max. 0.5 mA

Max. capacitive load

0.8 uF

Load wiring resistance

Max. 2.5Ω

AUX (Non-safety related output)

Output

Transistor output
(Only advanced function type has two outputs.)

Max. load current

50 mA

Residual voltage (during ON)

Max. 2.5 V(with a cable of 5 m)
Max. 3.5 V(with a cable of 31 m)

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

Approx. 5 mA
(For advanced function type only)

Lock control input

Approx. 2.5 mA

OSSD operation switchin input

Approx. 2.5 mA
(For advanced function type only)

Applicable Standards (Safety)

EN61508, IEC61508(SIL3), EN ISO13849-1:2015(PL e, Category 4),
EN ISO14119(Type4), IEC60947-5-3, EN60947-5-3, UL 60947-5-2

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10% or less, Class2)

Power consumption

6 W

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Operating ambient temperature

-20 to 55°C(No freezing)

Storage temperature

-25 to 70°C(No freezing) *4

Operating relative humidity

5% to 95%RH

Storage relative humidity

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm,
5 minutes in each of the X, Y, and Z directions
(IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis
(IEC 60947-5-3)

Material

Main unit

PBT, PET/PAR, TPC, PC, Nickel-plated steel

Actuator

PBT, Painted steel, Nickel-plated steel

Mounting bracket

Aluminum (Plate and screw: Steel)

Weight

Main unit

Approx.480 g

Actuator

Approx.250 g

*1 When the actuator is pulled first after unlocked, the holding force increases.
*2 Due to the flexible structure of the actuator, the guard can open 3.8 mm larger than the "Sar". The clearance between the actuator and the main unit may be narrowed by a maximum of 2.3 mm due to the magnet power built into the actuator.
*3 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of cascaded units -1).
*4 When stored for a long period of time, please store it at temperature of 55°C or lower.